<?xml version="1.0" encoding="UTF-8"?>
<feed xmlns="http://www.w3.org/2005/Atom">
   <title>Focal Corporation English Sphygmomanometer</title>
   <link rel="alternate" type="text/html" href="http://www.focalco.com/en/product/sphygmomanometer/" />
   <link rel="self" type="application/atom+xml" href="http://www.focalco.com/en/product/sphygmomanometer/atom.xml" />
   <id>tag:www.focalco.com,2011:/en/product/sphygmomanometer//6</id>
   <updated>2009-12-10T00:30:32Z</updated>
   
   <generator uri="http://www.sixapart.com/movabletype/">Movable Type 3.34</generator>

<entry>
   <title>FC-100V  Aneroid Sphygmomanometer，Complete with Velcro Cuff</title>
   <link rel="alternate" type="text/html" href="http://www.focalco.com/en/product/sphygmomanometer/2007/05/fc100v_aneroid_sphygmomanomete.html" />
   <id>tag:www.focalco.com,2007:/en/product/sphygmomanometer//6.73</id>
   
   <published>2007-05-28T02:18:23Z</published>
   <updated>2009-12-10T00:30:32Z</updated>
   
   <summary>
FC-100V</summary>
   <author>
      <name>focal</name>
      <uri>http://www.focalco.com/</uri>
   </author>
   
   
   <content type="html" xml:lang="ja" xml:base="http://www.focalco.com/en/product/sphygmomanometer/">
      <![CDATA[<img alt="fc-100v.jpg" src="http://www.focalco.com/product/fc-100v.jpg" width="498" height="332" />]]>
      <![CDATA[[&nbsp;Aneroid Sphygmomanometer&nbsp;Related&nbsp;Products&nbsp;]
FC-100H  Aneroid Sphygmomanometer，Complete with Hook cuff
FC-100D  Aneroid Sphygmomanometer，Complete with D‐ring Velcro Cuff]]>
   </content>
</entry>
<entry>
   <title>FC-101 Aneroid Sphygmomanometer，Home Use with Stethoscope</title>
   <link rel="alternate" type="text/html" href="http://www.focalco.com/en/product/sphygmomanometer/2007/05/fc101_aneroid_sphygmomanometer.html" />
   <id>tag:www.focalco.com,2007:/en/product/sphygmomanometer//6.74</id>
   
   <published>2007-05-28T02:18:23Z</published>
   <updated>2009-12-10T00:30:32Z</updated>
   
   <summary>
FC-101</summary>
   <author>
      <name>focal</name>
      <uri>http://www.focalco.com/</uri>
   </author>
   
   
   <content type="html" xml:lang="ja" xml:base="http://www.focalco.com/en/product/sphygmomanometer/">
      <![CDATA[<img alt="fc-101.jpg" src="http://www.focalco.com/product/fc-101.jpg" width="498" height="332" />]]>
      
   </content>
</entry>
<entry>
   <title>FC-108 Large Aneroid Sphygmomanometer, Desk Model with Velcro Cuff</title>
   <link rel="alternate" type="text/html" href="http://www.focalco.com/en/product/sphygmomanometer/2007/05/fc106_large_aneroid_sphygmoman.html" />
   <id>tag:www.focalco.com,2007:/en/product/sphygmomanometer//6.75</id>
   
   <published>2007-05-28T02:18:23Z</published>
   <updated>2009-12-10T00:30:32Z</updated>
   
   <summary>
FC-108</summary>
   <author>
      <name>focal</name>
      <uri>http://www.focalco.com/</uri>
   </author>
   
   
   <content type="html" xml:lang="ja" xml:base="http://www.focalco.com/en/product/sphygmomanometer/">
      <![CDATA[<img alt="bigface.jpg" src="http://www.focalco.com/product/bigface.jpg" width="498" height="332" />]]>
      <![CDATA[[&nbsp;Large Aneroid Sphygmomanometer&nbsp;Related&nbsp;Products&nbsp;]
FC-105  Large Aneroid Sphygmomanometer,Wall Model with Velcro Cuff
FC-106 Large Aneroid Sphygmomanometer, Clamp Model with Velcro Cuff
FC-107  Large Aneroid Sphygmomanometer,Stand Model with Casters and Velcro Cuff]]>
   </content>
</entry>
<entry>
   <title>FC-110  Mercurial Sphygmomanometer, Desk Model with Velcrocuff, CE type, inner Diameter 3.5mm Glass Tube </title>
   <link rel="alternate" type="text/html" href="http://www.focalco.com/en/product/sphygmomanometer/2007/05/fc110_mercurial_sphygmomanomet.html" />
   <id>tag:www.focalco.com,2007:/en/product/sphygmomanometer//6.76</id>
   
   <published>2007-05-28T02:18:23Z</published>
   <updated>2009-12-10T00:30:32Z</updated>
   
   <summary>
FC-110</summary>
   <author>
      <name>focal</name>
      <uri>http://www.focalco.com/</uri>
   </author>
   
   
   <content type="html" xml:lang="ja" xml:base="http://www.focalco.com/en/product/sphygmomanometer/">
      <![CDATA[<img alt="fc-110.jpg" src="http://www.focalco.com/product/fc-110.jpg" width="498" height="332" />]]>
      
   </content>
</entry>
<entry>
   <title>FC-110DELUXE  Mercurial Sphygmomanometer, Desk Model with Velcro Cuff，CE type, Inner Diameter 4mm Glass Tube</title>
   <link rel="alternate" type="text/html" href="http://www.focalco.com/en/product/sphygmomanometer/2007/05/fc110deluxe_mercurial_sphygmom.html" />
   <id>tag:www.focalco.com,2007:/en/product/sphygmomanometer//6.77</id>
   
   <published>2007-05-28T02:18:23Z</published>
   <updated>2009-12-10T00:30:32Z</updated>
   
   <summary>
FC-110DELUXE</summary>
   <author>
      <name>focal</name>
      <uri>http://www.focalco.com/</uri>
   </author>
   
   
   <content type="html" xml:lang="ja" xml:base="http://www.focalco.com/en/product/sphygmomanometer/">
      <![CDATA[<img alt="fc-110dx.jpg" src="http://www.focalco.com/en/product/fc-110dx.jpg" width="498" height="332" />]]>
      <![CDATA[<a href="http://www.focalco.com/en/product/sphygmomanometer/meter.jpg" target="blank"><img alt="meter-button.jpg" src="http://www.focalco.com/en/product/sphygmomanometer/meter-button.jpg" width="85" height="60" class="no_boder"/></a>]]>
   </content>
</entry>
<entry>
   <title>FC-113  Mercurial Sphygmomanometer,Stand Model with Casters and Velcro Cuff</title>
   <link rel="alternate" type="text/html" href="http://www.focalco.com/en/product/sphygmomanometer/2007/05/fc113_mercurial_sphygmomanomet.html" />
   <id>tag:www.focalco.com,2007:/en/product/sphygmomanometer//6.78</id>
   
   <published>2007-05-28T02:18:23Z</published>
   <updated>2009-12-10T00:30:32Z</updated>
   
   <summary>
FC-113</summary>
   <author>
      <name>focal</name>
      <uri>http://www.focalco.com/</uri>
   </author>
   
   
   <content type="html" xml:lang="ja" xml:base="http://www.focalco.com/en/product/sphygmomanometer/">
      <![CDATA[<img alt="fc-100stand.jpg" src="http://www.focalco.com/product/fc-100stand.jpg" width="498" height="332" />]]>
      
   </content>
</entry>
<entry>
   <title>FC-170D  Digital Blood Pressure Monitor，Semi‐Automatic type</title>
   <link rel="alternate" type="text/html" href="http://www.focalco.com/en/product/sphygmomanometer/2007/05/fc170d_digital_blood_pressure.html" />
   <id>tag:www.focalco.com,2007:/en/product/sphygmomanometer//6.79</id>
   
   <published>2007-05-28T02:18:23Z</published>
   <updated>2009-12-10T00:30:32Z</updated>
   
   <summary>
FC-170D</summary>
   <author>
      <name>focal</name>
      <uri>http://www.focalco.com/</uri>
   </author>
   
   
   <content type="html" xml:lang="ja" xml:base="http://www.focalco.com/en/product/sphygmomanometer/">
      <![CDATA[<img alt="fc-170d.jpg" src="http://www.focalco.com/product/fc-170d.jpg" width="498" height="332" />]]>
      <![CDATA[<h3>■LARGE LIQUID CRYSTAL DISPLAY</h3>
<p>The new large LCD is designed for easy reading.</p>
<h3>■AUTOMATIC DEFLATION</h3>
<p>Air release is automatically done by constant speed deflation system.<br />					The remaining air in the cuff may be rapidly exhausted by pressing air exhausted button.</p>
<h3>■MEMORY</h3>
<p>The last measurement of systoric and diastolic blood pressure values are displayed			when the power switch is pressed.</p>
<h3>■SPECIALLY DESIGNED CUFF</h3>
<p>A wrist cuff is exclusively designed for FC-300D for accurate measurement and to eliminate troubles of cuff wrapping. The Cuff is designed to be combined to the unit.</p>
<h3>■AUTOMATIC PRESSURE SELECTION</h3>
<p>The unit automatically selects proper inflation pressure (180, 210, 240 or 280 mmHg).</p>
<h3>■AUTO POWER OFF</h3>
<p>The unit is automatically switched off in approx. 3 minutes after use.</p>
		
<h3>SPECIFICATIONS</h3>	

<table width="498" border="3" cellpadding="2" cellspacing="1" bordercolor="#000000">
  <tr>
    <td width="40%" rowspan="5">Function</th>
    <td width="60%">Blood pressure measurement</th>  </tr>
  <tr>
    <td>Pulse rate measurement</td>
  </tr>
  <tr>
    <td>Automatic deflation</td>
  </tr>
  <tr>
    <td>1 Memory</td>
  </tr>
  <tr>
    <td>Automatic power off</td>
  </tr>
  <tr>
    <td rowspan="4">Indicator</td>
    <td>Systolic Blood pressure 3 digits</td>
  </tr>
  <tr>
    <td>Diastolic Blood pressure 3 digits</td>
  </tr>
  <tr>
    <td>Pulse rate 3 digits</td>
  </tr>
  <tr>
    <td>4 state symbols</td>
  </tr>
  <tr>
    <td>Measuring principl</td>
    <td>Oscillo-metric method</td>
  </tr>
  <tr>
    <td rowspan="2">Measuring ｒange</td>
    <td>Pressure 0 to 280 mmHg</td>
  </tr>
  <tr>
    <td>Pulse 40 to 200 pulses/min.</td>
  </tr>
  <tr>
    <td rowspan="2">Accuracy</td>
    <td>±3 mmHg (Cuff pressure)</td>
  </tr>
  <tr>
    <td>±5% of reading (Pulse rate)</td>
  </tr>
  <tr>
    <td>Inflation</td>
    <td>Manual (by rubber bulb)</td>
  </tr>
  <tr>
    <td>Deflation</td>
    <td>Automatic air release system and <br />
 quick deflation by manual push button</td>
  </tr>
  <tr>
    <td>Battery</td>
    <td>4 pcs.  &quot;AA&quot; size batteries (R6P,LR6)</td>
  </tr>
  <tr>
    <td>Battery life</td>
    <td>Approx. 1000 times /R6P</td>
  </tr>
  <tr>
    <td>Main unit size</td>
    <td>86(W) × 120(D）×38.7(H) mm</td>
  </tr>
  <tr>
    <td>Main unit weight</td>
    <td>Approx. 96 grams</td>
  </tr>
  <tr>
    <td>Electric shock  protection</td>
    <td>Type B equipment</td>
  </tr>
</table>
<p>* specifications are subject to change without notice due to improvement in performance.	</p>					]]>
   </content>
</entry>
<entry>
   <title>FC-200D Digital Blood Pressure Monitor，Full‐Automatic type</title>
   <link rel="alternate" type="text/html" href="http://www.focalco.com/en/product/sphygmomanometer/2007/05/fc200d_digital_blood_pressure.html" />
   <id>tag:www.focalco.com,2007:/en/product/sphygmomanometer//6.80</id>
   
   <published>2007-05-28T02:18:23Z</published>
   <updated>2009-12-10T00:30:32Z</updated>
   
   <summary>
FC-200D</summary>
   <author>
      <name>focal</name>
      <uri>http://www.focalco.com/</uri>
   </author>
   
   
   <content type="html" xml:lang="ja" xml:base="http://www.focalco.com/en/product/sphygmomanometer/">
      <![CDATA[<img alt="fc-200d.jpg" src="http://www.focalco.com/en/product/fc-200d.jpg" width="498" height="332" />]]>
      <![CDATA[<h3>■LARGE LIQUID CRYSTAL DISPLAY</h3>
<p>The new large LCD is designed for easy reading.</p>
<h3>■AUTO INFLATION AND DEFLATION</h3>
<p>A single touch of button makes all measurement sequences automatic,
including cuff  inflation, deflation and air exhaust after measurement.</p>
<h3>■MEMORY</h3>
<p>7 memories and average will be displayed by press the memory button.</p>
<h3>■AUTO POWER OFF</h3>
<p>The unit is automatically switched off in approx. 3 minutes after use.</p>
		
<h3>SPECIFICATIONS</h3>	

<table width="498" border="3" cellpadding="2" cellspacing="1" bordercolor="#000000">
  <tr>
    <td width="40%" rowspan="5">Function</th>
    <td width="60%">Blood pressure measurement</th>  </tr>
  <tr>
    <td>Pulse rate measurement</td>
  </tr>
  <tr>
    <td>Automatic deflation</td>
  </tr>
  <tr>
    <td>7 Memory</td>
  </tr>
  <tr>
    <td>Automatic power off</td>
  </tr>
  <tr>
    <td rowspan="4">Indicator</td>
    <td>Systolic Blood pressure 3 digits</td>
  </tr>
  <tr>
    <td>Diastolic Blood pressure 3 digits</td>
  </tr>
  <tr>
    <td>Pulse rate 3 digits</td>
  </tr>
  <tr>
    <td>4 state symbols</td>
  </tr>
  <tr>
    <td>Measuring principl</td>
    <td>Oscillo-metric method</td>
  </tr>
  <tr>
    <td rowspan="2">Measuring ｒange</td>
    <td>Pressure 0 to 280 mmHg</td>
  </tr>
  <tr>
    <td>Pulse 40 to 200 pulses/min.</td>
  </tr>
  <tr>
    <td rowspan="2">Accuracy</td>
    <td>±3 mmHg (Cuff pressure)</td>
  </tr>
  <tr>
    <td>±5% of reading (Pulse rate)</td>
  </tr>
  <tr>
    <td>Inflation</td>
    <td>Automatic air inflational by internal pump</td>
  </tr>
  <tr>
    <td>Deflation</td>
    <td>Automatic constant speed deflation system</td>
  </tr>
  <tr>
    <td>Battery</td>
    <td>4 pcs.  "AA" size batteries (R6P,LR6)</td>
  </tr>
  <tr>
    <td rowspan="2">Battery life</td>
    <td>Approx. 1000 times /R6P</td>
  </tr>
 <tr>
    <td>Approx. 200 times /LR6</td>
 </tr>
  <tr>
    <td>Main unit size</td>
    <td>148(W) × 136(D）×56.5(H) mm</td>
  </tr>
  <tr>
    <td>Main unit weight</td>
    <td>Approx. 280 grams</td>
  </tr>
  <tr>
    <td>Electric shock  protection</td>
    <td>Type B equipment</td>
  </tr>
</table>
<p>* specifications are subject to change without notice due to improvement in performance.	</p>					]]>
   </content>
</entry>
<entry>
   <title>FC-300D  Digital Blood Pressure Monitor，Wrist Watch type</title>
   <link rel="alternate" type="text/html" href="http://www.focalco.com/en/product/sphygmomanometer/2007/05/fc300d_digital_blood_pressure.html" />
   <id>tag:www.focalco.com,2007:/en/product/sphygmomanometer//6.81</id>
   
   <published>2007-05-28T02:18:23Z</published>
   <updated>2009-12-10T00:30:32Z</updated>
   
   <summary>
FC-300D</summary>
   <author>
      <name>focal</name>
      <uri>http://www.focalco.com/</uri>
   </author>
   
   
   <content type="html" xml:lang="ja" xml:base="http://www.focalco.com/en/product/sphygmomanometer/">
      <![CDATA[<img alt="fc-300D_listtype.jpg" src="http://www.focalco.com/en/product/fc-300D_listtype.jpg" width="498" height="332" />]]>
      <![CDATA[<h3>■BLOOD PRESSURE MEASUREMENT</h3>
<p>The last measurement of systoric and diastolic blood pressure values are displayed
when the power switch is pressed.							
</p>
<h3>■AUTOMATIC DEFLATION</h3>
<p>A wrist cuff is exclusively designed for FC-300D for accurate measurement and
to eliminate troubles of cuff wrapping. The Cuff is designed to be combined to the unit.</p>
<h3>■AUTOMATIC PRESSURE SELECTION</h3>
<p>The unit automatically selects proper inflation pressure (180, 210, 240 or 280 mmHg).</p>
<h3>■AUTO POWER OFF</h3>
<p>The unit is automatically switched off in 3 minutes after use.</p>
		
<h3>SPECIFICATIONS</h3>	
<table width="498" border="3" cellpadding="2" cellspacing="1" bordercolor="#000000">
  <tr>
    <td colspan="2" rowspan="6">Function</th>
    <td width="60%">Blood pressure measurement</th>  </tr>
  <tr>
    <td>Pulse rate measurement</td>
  </tr>
  <tr>
    <td>Automatic inflation and deflatio</td>
  </tr>
  <tr>
    <td>Memory</td>
  </tr>
  <tr>
    <td>Automatic power off</td>
  </tr>
  <tr>
    <td>Automatic pressure selection<br />
(180 / 210 / 240 / 280 mmHg)</td>
  </tr>
  <tr>
    <td colspan="2" rowspan="4">Indicator</td>
    <td> 7 digits L.C.D.</td>
  </tr>
  <tr>
    <td>Systoric / Diastolic / Pulse rate</td>
  </tr>
  <tr>
    <td> 2 error messages</td>
  </tr>
  <tr>
    <td>4 state symbols</td>
  </tr>
  <tr>
    <td colspan="2">Operating principle</td>
    <td>Oscillo-metric method</td>
  </tr>
  <tr>
    <td colspan="2" rowspan="2">Measuring ｒange</td>
    <td>0 to 280 mmHg (Cuff pressure)</td>
  </tr>
  <tr>
    <td>40 to 200 pulses/min. (Pulse rate)</td>
  </tr>
  <tr>
    <td colspan="2" rowspan="2">Accuracy</td>
    <td>±3 mmHg (Cuff pressure)</td>
  </tr>
  <tr>
    <td>±5% of reading (Pulse rate)</td>
  </tr>
  <tr>
    <td colspan="2">Inflation</td>
    <td>Automatic inflation pump</td>
  </tr>
  <tr>
    <td colspan="2">Deflation</td>
    <td>Automatic air release valve</td>
  </tr>
  <tr>
    <td colspan="2">Exhaust</td>
    <td>Automatic exhaust valve</td>
  </tr>
  <tr>
    <td colspan="2">Cuff</td>
    <td>Hard cuff</td>
  </tr>
  <tr>
    <td colspan="2">Battery</td>
    <td>2 pcs.  (LR03/AAA)</td>
  </tr>
  <tr>
    <td colspan="2">Battery life</td>
    <td>Approx. 300 times /LR03</td>
  </tr>
  <tr>
    <td width="20%" rowspan="3">Size</td>
    <td width="20%">Main unit</td>
    <td>74(W) × 72(D）×31(H) mm</td>
  </tr>
  <tr>
    <td>Cuff unit</td>
    <td>70 × 290 mm</td>
  </tr>
  <tr>
    <td>Wrist circumference</td>
    <td>135 ～ 195 mm</td>
  </tr>
  <tr>
    <td colspan="2">Weight (Main unit)</td>
    <td>Approx. 135 gram</td>
  </tr>
  <tr>
    <td colspan="2">Electric shock  protection</td>
    <td>Type B equipment</td>
  </tr>
</table>
<p>* specifications are subject to change without notice due to improvement in performance.	</p>					]]>